HomedatasheetD06D60

D06D60 Datasheet

N/A0.005-100 Amps DC0-60 Volts DC3.5-32 Control - Volts DC
Share:
Manufacturer

Description

Features, Applications

60-100Amp 0-60 Vdc DC Output MOSFET Output Low On-State Resistance High Current Ratings Panel Mount

DC output relays feature MOSFET tech nology for low on-state resistance, assuring easy paralleling and switching capabilities to 100 amps at 60 Vdc. Lower current models are also available to 500 Vdc. All models come in Crydom's standard panel-mount package. Manufactured in Crydom's ISO 9001 Certified facility for optimum product performance and reliability.

Operating Voltage Range [Vdc] Max. Load Current

Min. Load Current [mA] Max. Surge Current, [Adc] (10msec) Max. On-State Voltage Drop @ Rated Current [Vdc] Thermal Resistance Junction to Case JC ) [C/W] Max On-state Resistance @ Rated Current (R DS-ON) [Ohms] Max. Off-State Leakage Current @ Rated Voltage [mA] Max. Turn-On Time [�sec] Max. Turn-Off Time [msec]

Control Voltage Range Maximum Turn-On Voltage Minimum Turn-Off Voltage Nominal Input Impedance Maximum Input Current

�2000 CRYDOM CORP, Specifications subject to change without notice.

All parameters 25� C unless otherwise specified. Dielectric strength and insulation resistance are measured between input and output. Heat sinking required, for derating curves see page 2. Input circuitry incorporates active current limiter.

For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: (0)1202 365070 FAX (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY:

GENERAL SPECIFICATIONS Dielectric Strength 60Hz Insulation Resistance (Min.) @ 500 Vdc Max. Capacitance Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range MECHANICAL SPECIFICATIONS Weight: (typical) Encapsulation: Terminals:

Input and output polarity must be observed. Inductive loads must be diode suppressed.

All loads are inductive, even ones that are not so labeled. An inductive load will produce harmful transient voltages when it is turned off. The more perfect the switch, the larger the transient voltages; the MOSFET output is so nearly an ideal switch that the transient voltages produced by seemingly "non-inductive" loads can cause damage if not suppressed. Diodes should be fast recovery type with PIV rated greater than supply voltage.

Screw Torque Requirements: 6-32 Screws - 10 in./lbs., 8-32 and 10-32 Screws - 20in./lbs. (Screws dry without grease.)

For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: (0)1202 365070 FAX (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY:


Features

Parameters

Download DataSheet PDF View and Download


Manufacturer information

Warm Hint

What HQEW.NET can offer here?
1. www.hqew.net/product-data provides numerous and various electronic part data-sheet and technology document here., if it can't be shown, Please feel free to ask us for it.
2. www.hqew.net/news provides the latest information of the semiconductor industry or the electronics industry for you.
3. www.hqew.net provides verified suppliers and numerous electronic components for your demand and business.
Any questions you can contact us by email cs@hqew.net.
related datasheet
Browse Alphabetically: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 0 1 2 3 4 5 6 7 8 9
Contact Us

+86-755-83536845

One to One Customer Service

17190417227