Sealed, Compact, Slim Prewired Limit Switch

s Rugged diecast housing s Meets UL types 3, 4 and 13 s Triple-sealed construction s Designed for easy gang mounting s Rated load of 5 amps, 250 VAC s Prewired with m (9.8 ft) or

Actuator Pin plunger Sealed plunger Roller plunger Sealed roller plunger Cross roller plunger Sealed cross roller plunger Bevel plunger Coil spring Roller lever m (9.8 ft) cable m (16.4 ft) cable (See Note.) D4C-1750 D4C-1720

Note: 5 m cable types are available on special order only.
Specifications

Model Rated voltage Non-inductive load Resistive load D4C-1 125 VAC 250 VAC 8 VDC 14 VDC 30 VDC 125 VDC 250 VDC 0.2 A Lamp load 0.03 A Inductive load Inductive load 0.2 A Motor load 20 A max 10 A max Inrush current

Note: 1. Inductive loads have a power factor of 0.4 min. (AC) and a time constant 7 ms max. (DC). 2. Lamp loads have an inrush current of 10 times the steady-state current. 3. Motor loads have an inrush current of 6 times the steady-state current.

Operating speed Operating frequency Insulation resistance Rated insulation voltage (Ui) Rated impulse withstand voltage (Uimp) Switching overvoltage Short-circuit protective device Conditional short-circuit current Contact resistance Dielectic strength Mechanical Electrical to 0.5 m/s to 1 m/s) 120 operations/min 30 operations/min 100 M min. (at 500 VDC) (IEC947-5-1) 1,000 VAC, 300 VDC max. 10 A fuse (type gG) 400 m (initial value with 3 m VCTF cable) (initial value with 5 m VCTF cable)

1,000 VAC, 50/60 Hz for 1 min between non-continuous terminals 1,500 VAC, 50/60 Hz for 1 min between current-carrying metal part and ground, and between each terminal and non-current-carrying metal part Malfunction Destruction Malfunction Operating Mechanical Electrical UL NEMA IEC to 55 Hz, 1.5 mm double amplitude Approx. 1,000 m/s2 (approx. 100 G) Approx. 500 m/s2 (approx. 158�F) 95% max Pollution degree (IEC947-5-1) 10,000,000 operations min. (at 2 mm OT) See: Engineering Data Types 3, 4 and 13 Types 3, 3R, and 13 IP67 With 3 m VCTF cable: 360 g With 5 m VCTF cable: 540 g

Vibration resistance Shock resistance Ambient temperature Ambient humidity Life expectancy Enclosure ratings

Legend: OF = Operating Force (max.); RF = Reset Force (min.); OT = Overtravel (min.); PT = Pretravel MD = Movement Differential (max.); OP = Operating Position Part number D4CD4CD4CD4CD4CD4CD4CD4CD4C01 Description Pin plunger Sealed plunger Roller plunger Sealed roller plunger Cross roller plunger Sealed cross roller plunger Bevel plunger Coil spring Roller lever kg (42.32 oz) kg (63.49 oz) kg (42.32 oz) kg (63.49 oz) kg (42.32 oz) kg (63.49 oz) kg (42.32 oz) g (5.29 oz) g (20.46 oz) g (15.87 oz) g (15.87 oz) g (15.87 oz) g (15.87 oz) g (15.87 oz) g (15.87 oz) g (15.87 oz) g (5.29 oz) mm (0.118 in) mm (0.118 in) mm (0.118 in) mm (0.118 in) mm (0.118 in) mm (0.118 in) mm (0.118 in) mm (0.07 in) mm (0.07 in) mm (0.07 in) mm (0.07 in) mm (0.07 in) mm (0.07 in) mm (0.07 in) mm (0.008 in) mm (0.008 in) mm (0.008 in) mm (0.008 in) mm (0.008 in) mm (0.008 in) mm (0.008 in) (0.62 �0.04 in) (0.99 �0.04 in) (1.12 �0.04 in) (1.35 �0.04 in) (1.12 �0.04 in) (1.35 �0.04 in) (1.12 �0.04 in)


Features

Parameters

Download DataSheet PDF View and Download


Manufacturer information

Warm Hint

What HQEW.NET can offer here?
1. www.hqew.net/product-data provides numerous and various electronic part data-sheet and technology document here., if it can't be shown, Please feel free to ask us for it.
2. www.hqew.net/news provides the latest information of the semiconductor industry or the electronics industry for you.
3. www.hqew.net provides verified suppliers and numerous electronic components for your demand and business.
Any questions you can contact us by email cs@hqew.net.
related datasheet
Browse Alphabetically: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 0 1 2 3 4 5 6 7 8 9
Contact Us

+86-755-83536845

One to One Customer Service

17190417227